- 1330 - Bass Tool & Supply, Inc. Houston Email Fax Toll Free www.basstool.com (713) 682-1889
[email protected] (713) 681-4931 800-442-0042 MODEL NO. SJ-210 PART# MTI- 178-561-11A 178-561-12A 178-563-11A 178-563-12A 178-565-11A 178-565-12A DRIVE UNIT Standard type (178-230-3) Retractable type (178-235) Transverse tracing type (178-233-2) DETECTOR 0.75mN type (178-296) 4mN type (178-390) 0.75mN type (178-296) 4mN type (178-390) 0.75mN type (178-387) 4mN type (178-386) DISPLAY UNIT Compact type (178-253A) DETECTOR: CONICAL TAPER ANGLE 60º 90º 60º 90º 60º 90º STYLUS TIP RADIUS 2µm 5µm 2µm 5µm 2µm 5µm DETECTOR MEASURING FORCE 0.75mN 4mN 0.75mN 4mN 0.75mN 4mN MODEL NO. SJ-310 PART# MTI- 178-571-11A 178-571-12A 178-573-11A 178-573-12A 178-575-11A 178-575-12A DRIVE UNIT Standard type (178-230-2) Retractable type (178-235) Transverse tracing type (178-233-2) DETECTOR 0.75mN type (178-296) 4mN type (178-390) 0.75mN type (178-296) 4mN type (178-390) 0.75mN type (178-387) 4mN type (178-386) DISPLAY UNIT Standard type with printer DETECTOR: CONICAL TAPER ANGLE 60º 90º 60º 90º 60º 90º STYLUS TIP RADIUS 2µm 5µm 2µm 5µm 2µm 5µm DETECTOR MEASURING FORCE 0.75mN 4mN 0.75mN 4mN 0.75mN 4mN SURFACE ROUGHNESS TESTERS SJ-210 Technical Data: SJ-210 X axis (drive unit) Measuring range: .70”, 22” (17.5, 5.6mm (Transverse tracing drive unit type)) Measuring speed: .01”, .02”, .03” /s (0.25, 0.5,0.75mm/s .039” /s (1mm/s) (Returning)) Detector Range: 360µm (-200µm to +160µm) Measuring method: skidded Measuring force: 0.75mN or 4mN Stylus tip: Diamond, 90º / 5µmR (60º / 2µmR) Skid radius of curvature: 40mm Skid force: less than 400mN Type: Differential inductance Power supply: Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter Charging time: about 4 hours (may vary due to ambient temperature) Endurance: about 1000 measurements (differs slightly due to use conditions/ environment) External I/O: USB I/F, Digimatic Output, Printer Output, RS-232C I/F, Foot SW I/F Data storage: Memory card (option 12AAL069) Dimensions (W x D x H) Display unit: 2.05x2.59x6.3” (52.1 x 65.8 x 160mm) Drive unit: 6.85x2.59x2” (115 x 23 x 26mm) Weight: About 1.1lb (0.5kg) (Display unit + Drive unit + Standard detector) CALL US FOR A COMPLETE OFFERING OF THE MTI SURFTEST LINE AND OPTIONAL ACCESSORIES ● The 2.4-inch color graphic LCD provides excellent readability and an intuitive display that is easy to negotiate. The LCD also includes a backlight for improved visibility in dark environments. ● The Surftest SJ-210 can be operated easily using the buttons on the front of the unit and under the sliding cover. ● Up to 10 measurement conditions and one measured profile can be stored in the internal memory. ● An optional memory card can be used as an extended memory to store large quantities of measured profiles and conditions. Functions: SJ-210 Customization: Desired parameters can be selected for calculation and display. GO/NG judgement: By max value / 16% / Standard deviation Storage of measurement condition: Save the conditions at power OFF Storage: Internal memory: Measurement condition (10sets), Measured profile (1set) Memory card (Option): 500 measurement conditions, 10000 measured profiles, 500 display images Text file (Measurement conditions / Measured profile / Assessed profile / Bearing area curve / Amplitude distribution curve) Calibration: Auto-calibration with the entry of numerical value / Average calibration with multiple measurement (Max 5 times) is available. SJ-310 SERIES 178 - Portable Surface Roughness Tester Technical Data: SJ-310 X axis (drive unit) Measuring range: .70”, .22”(17.5, 5.6mm (Transverse tracing drive unit type)) Measuring speed: .01”, .02”, .03” /s(0.25, 0.5, 0.75mm/s .039” /s (1mm/s) (Returning)) Detector Range: 360µm (-200µm to +160µm) Measuring method: skidded Measuring force: 0.75mN or 4mN Stylus tip: Diamond, 90º / 5µmR (60º / 2µmR) Skid radius of curvature: 40mm Skid force: less than 400mN Type: Differential inductance Power supply: Two-way power supply: battery (rechargeable Ni-MH battery) and AC adapter Battery: Charging time: 4 hours maximum Recharge cycles: Approximately 1500 times (slightly varies with the usage and environmental conditions) External I/O: USB I/F, Digimatic Output, RS-232C I/F, External SW I/F Data storage: Memory card (option 12AAL069) Dimensions (W x D x H) Control unit: 10.8x4.29x7.8” (275 x 109 x 198mm) Drive unit: 6.85x2.59x2” (115 x 23 x 26mm) Weight: Display unit: Approx. 3.7lb(1.7kg) Drive unit: .4lb(0.2kg) Functions: SJ-310 Customization: Desired parameters can be selected for calculation and display. Statistical processing: Maximum value, minimum value, mean value, standard deviation, pass rate, histogram of each parameter GO/NG judgement: maximum value rule, 16% rule, average value rule, standard deviation (1σ, 2σ, 3σ) Storage: Internal memory: Measurement condition (10 sets) Memory card (Option): 500 measurement conditions, 10000 measured profiles, 500 display images, Text file (Measurement conditions / Measured profile / Assessed profile / Bearing area curve / Amplitude distribution curve), 500 statistical data, etc. Calibration: Auto-calibration with the entry of numerical value / Average calibration with multiple measurement (Max 12 times) is available Power saving function: Auto-sleep-function, Auto light-off of Backlight by ECO mode. ● Access to each feature can be password-protected, which prevents unintended operations and allows you to protect your settings. ● The display interface supports 16 languages, which can be freely switched. ● An alarm warns you when the cumulative measurement distance exceeds a preset limit. ● The Surftest SJ-210 complies with the following standards: JIS (JIS-B0601-2001, JIS-B0601-1994, JIS B0601-1982), VDA, ISO-1997, and ANSI. ● In addition to calculation results, the Surftest SJ-210 can display sectional calculation results and assessed profiles, load curves, and amplitude distribution curves. Evaluation Capability: SJ-210 Magnetic Stand Adapters Applicable standards: Assessed profiles: JIS ‘82, JIS ‘94, JIS ‘01, ISO ‘97, ANSI, VDA Primary profile, Roughness profile, DF profile, Roughness profile-Motif Ra, Rc, Ry, Rz, Rq, Rt, Rmax, Rp, Rv, R3z, Rsk, Rku, Rc, RPc, Rsm, Rz1max, S, HSC, RzJIS, Rppi, R∆a, R∆q, Rlr, Rmr, Rmr(c), Rδc, Rk, Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, Rpm, tp, Htp, R, Rx, AR, Possible Customize Analysis graphs: Bearing area curve / Amplitude distribution curve ● Complies with the following standards: JIS (JIS-B0601-2001, JIS-B0601-1994, JIS B0601-1982, VDA, ISO-1997, and ANSI. ● The Measure-Start and other frequently used buttons are strengthened to resist wear and the detrimental effects of workshop contaminants. Digital filters: Gaussian, 2CR75, PC75 Cutoff length: λc: .003”, .01”, .03”, .1” (0.08, 0.25, 0.8, 2.5mm) Sampling length: .003”, .01”,.03”,.1” λs: .1” , .3” (2.5, 8 m) Number of sampling lengths (x n): (0.08, 0.25, 0.8, 2.5mm) x1, x2, x3, x4, x5, x6, x7, x8, x9, x10 arbitrary length (0.3 to 16.0mm: 0.01mm interval) x1, x2, x3, x4, x5, x6, x7, x8, x9, x10 arbitrary length (0.3 to 5.6mm: 0.01mm interval)* ● The display interface supports 16 languages, which can be freely switched. ● 10 sets of measurement conditions can be saved in the measurement unit - an optional memory card can save measurement conditions and the measured profile. Evaluation Capability: SJ-310 Applicable Standards: JIS ‘82, JIS ‘94, JIS ‘01, ISO ‘97, ANSI, VDA Assessed profiles: P (primary profile), R (roughness profile), DIN4776, roughness motif, waviness motif Evaluation paramters: Ra, Ry, Rz, Rt, Rp, Rq, Rv, Rsk, Rku Rc, RSm, S, RPc, R3z, Rmr (c), Rpk, Rvk, Rδc, Rk, Mr1, Mr2, Lo, Rppi, R, AR, Rx, A1, A2, Vo, HSC, Rmr, SK, Ku, R∆a, R∆q, Rlr, a, q, Rpm, RzJIS (JIS ‘01),tp (ANSI),Htp (ANSI),Wte,Wx, W, AW, Rz1max (ISO), Rmax (VDA, ANSI, JIS ‘82), Possible Customize Analysis graphs: Bearing Area Curve (BAC), Amplitude Distribution Curve (ADC) Digital filters: 2CR, PC75, Gaussian Cutoff length: λc: .003”, .01”, .03”, .1”, .3” (0.08, 0.25, 0.8, 2.5, 8mm) λs: .1” , .3” (2.5, 8mm) Sampling length: .003”, .01”, .03”, .1”, .3” (0.08, 0.25, 0.8, 2.5, 8mm) Number of sampling lengths (x n): x1, x2, x3, x4, x5, x6, x7, x8, x9, x10 arbitrary length (0.3 to 16.0mm: 0.01mm interval) x1, x2, x3, x4, x5, x6, x7, x8, x9, x10 arbitrary length (0.3 to 5.6mm: 0.01mm interval)* *Only for Transverse tracing drive unit type Printer: Thermal type Printing width: Printing width: 48mm (paper width: 58mm) Recording magnification: Vertical magnification: 10X to 100,000X, Auto Horizontal magnification: 1X to 1,000X, Auto *Only for Transverse tracing drive unit type Evaluation parameters: Roughness specimen ● Ra: 118µinch (3µm), 394µinch (10µm) MTI-178-602 Step gage ● Steps:79µinch (2µm), 394µinch (10µm) MTI-178-612 SERIES 178 - Portable Surface Roughness Tester PART# MTI- Measuring Force Stylus profiles* Remarks column 178-385 0.75mN 2µmR/60º Not available for the transverse tracing drive unit 178-394 4 mN 5µmR/90º Deep groove detectors * Tip radius / Tip angles Nosepiece for cylindrical surfaces Nosepiece for cylindrical surfaces ● SJ-210/210R optional accessory. ● SJ-310/310R standard accessory. ● Not available for the transverse tracing drive unit ● ø30mm or smaller workpiece PART#: MTI-12AAA218 MTI-12AAA220 (3/8") MTI-12AAA221 (ø8mm)